Six Technical Points on POE in Compressor and Refrigeration Oils

Oct 23,2026

Rotary screw compressor: where POE earns its 8,000 hours

Whether a screw compressor survives 8,000 hours is often not about the compressor. It is about whether the refrigeration oil was selected correctly.

The short answer

POE (polyol ester) is the mainstream route for refrigeration oils and synthetic compressor oils because it solves both extremes at once: it can run continuously at about 200 °C and briefly above 300 °C (decomposition begins around 280 °C), while still flowing at about −60 °C. 

1. Six key properties of POE

PropertyBehaviourWhat it means for the equipment
Heat resistanceApprox. 200 °C continuous, 300 °C+ short termNo coking in screw machines with high discharge temperature
Low-temperature flowFlowable at approx. −60 °CReliable low-temperature oil return in refrigeration circuits
Viscosity indexGenerally 150+, some grades up to 220Stable viscosity across a wide temperature window
Anti-wear behaviourPolar molecules adsorb on metal surfaces, high film strengthLower start-up wear
VolatilityLow volatility; flash point approx. 280–300 °C, fire point approx. 320 °CLow evaporation loss, safer at high temperature
ToxicityNon-toxic; suitable for environmentally acceptable lubricantsMeets environmental requirements

2. POE's special position in refrigeration circuits

POE shows good compatibility across HFC refrigerant systems and hydrocarbon refrigerant systems  — which is why it became the mainstream refrigeration oil. MarkWide Research additionally notes that the EU F-Gas regulation phase-down is pushing compressor lubricant demand toward formulations compatible with low-GWP refrigerants — a structural tailwind for POE.

3. Three points that belong in your operating procedure

  1. Immiscible with mineral oil — a system previously run on mineral oil must have residual oil removed before switching to POE.
  2. Hygroscopic and hydrolytic — esters have moderate hydrolytic stability and absorb moisture readily; avoid open exposure. With water present and heat applied, they decompose.
  3. Seals and coatings — POE has a low aniline point (some polyol esters around 8 °C) and causes a degree of swelling in rubber seals and hoses, though less than diesters; blending in some PAO is a common mitigation.

4. What we supply

👉 Tell us your refrigerant type, discharge temperature and target oil-change interval. We will match the POE viscosity grade.

Contact us

Talk to the ICASON peroxide team

Tel: +86 16639328358    Whatsapp: +86 16639328358       Wechat: 166393238358            E-mail: icason001@icason.com

Online Message

* Note: Please be sure to fill in the information accurately and keep the communication unblocked, we will get in touch with you as soon as possible

%{tishi_zhanwei}%